Submitted by James Klim DDS, CADStar Host on 04/18/2011 - 2:55am

More will be coming to CEREC Liftoff chapter 5 on the Parameter(s) subject.  Just completed shooting another series on the latest Parameter(s) I use and how they all fit together.  In the meantime, the following webcast will provide a review for important scan principles and CEREC Parameter(s) calibration.

Submitted by James Klim DDS, CADStar Host on 03/23/2011 - 8:26pm

Submitted by James Klim DDS, CADStar Host on 03/23/2011 - 8:20pm

Seamless CEREC fits are a significant reflection from an accurate/technique oriented optical impression. Here is the deal,

1.  No pitching and rolling over preparations

2.  Take the least amount of overlaping optical captures to create an virtual die

3.  When rolling to the buccal for the buccal bite, do not roll over prep(s) or proximal contact(s) next to the preparation(s) See CEREC Liftoff Chapter 3 for further review.

Submitted by James Klim DDS, CADStar Host on 03/11/2011 - 7:35pm

Not sure of the wear factor yet, but something to keep an eye on.  The "bruxer" type of crown idea.  With my experience thus far, e.max is definitely a reliable material for the challenged occlusal situation as long as there is adequate ceramic thickness.  From what I am hearing in the industry, part of a material's wear compatibility factor is defined by the smoothness and polishability of the material.  Zirconia is a very smooth material.

 

Submitted by James Klim DDS, CADStar Host on 03/07/2011 - 5:01pm

It happens...open contact on a beautifully milled restoration. Otherwise, it is perfect.  Add-on porcelain technique is simple and can often be fired in conjunction with the glaze or crystallization cycle.  See webcast posted to chapter 6.

  

Submitted by James Klim DDS, CADStar Host on 01/12/2011 - 3:43am

 

  • Mixing palette for stains and glaze with transparent or black lid (Renfert)
  • 30 small wells for stains and glaze.
  • Great cover to use while storing stain and glaze to prevent drying out and keep contents fresh for continual multiple uses.
  • Article number: 10650100

Submitted by James Klim DDS, CADStar Host on 01/03/2011 - 8:07pm

Minor update: - optimized insertion axis calculation Sometimes during calculation of the restoration proposal an error message came up (like: 'error during calculation').  This has been fixed with this service pack.  There is no new upload software to the MC XL with this service patch. Download from http://bit.ly/9cYkVO

Submitted by James Klim DDS, CADStar Host on 01/02/2011 - 7:01am

Categories:

Happy New Year to all my CEREC Liftoff colleagues.  I am looking forward to this coming year and the CEREC world.  We will continue to evolve and add to CEREC Liftoff so you will value this site as a dental mentoring site for years to come. I spend as much time in the dental clincial trenches with CEREC chairside as I do teaching.  So what I bring to the mentoring table is what I do on a daily basis in the practice.  CEREC Liftoff is evolving to be more than CEREC, but also my practice style, systems, and philosophies. Thanks so much for signing up as members.  Each one of you are valuable. Happy New Year! Sincerely James

 

Submitted by James Klim DDS, CADStar Host on 12/22/2010 - 5:52am

  

Submitted by James Klim DDS, CADStar Host on 12/16/2010 - 6:54am

I just completed this case.  Subgingival margins on the distal due to cervical decay issues. Laser tissue retraction with the VITA Scan Spray will create very crisp and enhanced margins for optical capture. Restoration:  Full crown, e.max cement with SpeedCEM.